EMO-500

Operation and Programming Manual

12


Figure 4: Connecting five inputs to common

Never connect the shield to ground at both ends. Doing so can produce unwanted oscillations in the
signal wires.

External Resets and Controls (Hardware)

Five inputs to the 15-pin connector help provide extra control without having to go through the
keyboard. To activate the external resets and controls, connect the respective pin to the “Common for 1
– 5” pin. See Figure 4.

Pins 1 - 4 are edge-triggered; use
momentary contact switches to activate
them. Pin 5 (enable programming) is an
on/off function; use a single-pole toggle
switch for it. See Figure 5.

Caution

Figure 5: Pin 1-4 and Pin 5 connections