EMO-500

Operation and Programming Manual

22


Flow B

Flow A+B

If you select any function other than Ratio A/B for the Limit 2 Rule, the EMO-500 still monitors the ratio
of flow A/B, but no Warning or Alarm trips when flow is out of the error percentages. Display 5 indicates
“NO RATIO MODE FOR LIMITS 1 & 2.”

F5

In the Meters/Units programming section, you select from nine Flow Meters and three Engineering
Units. Scroll through the Meters until the selection desired appears on the display and enter your
selection with the F6 key. The EMO-500 automatically enters the Rate Scaling Factors (KFR) and Total
Scaling Factors (KFT) for each of the selections below.

Flow Meter Approximate K-factor

ZHM01

160000 PPG

ZHM03

6600 PPG

HPM-15

32000 PPG

ZHM02

1.32000 PPG

ZHM04

1800 PPG

HPM-20

16000 PPG

ZHM02

16000 PPG

ZHM05

500 PPG

HPM-30

6600 PPG

The unit then asks you to select the Engineering Units in the same manner. Choose from:

CC & CCPM

GAL & GPM

OZ & OZM

The EMO-500 flashes “Direct Selection, Meter A or B” and the display reads “F2=A, F3=B, F4=A&B.” This
is where you choose the Flow Meter and set the Engineering Unit. The display reads “More Selections?,
F2=Yes, F3=No.” If both Flow Meters are programmed, select F3; if not, press F2 to start the
Meters/Units Program section again.