Ft for a (default 10000), Emo-500 – AW Gear Meters EMO-500 User Manual

Page 26

Advertising
background image

EMO-500

Operation and Programming Manual

25


6000

K -factor

Enter this KFR number in the Global Programming section. The K-factor is the number the manufacturer
provides as the average K-factor for the transmitter.

For example, a flow meter has the K-factor 2053.7 imp/GAL and the display should show
Gallons/minute.

6000

2053.7

Enter 2921 as the KFR; use the DP (decimal point) key to move the DP to the number 2.921.

Calculator mathematics produce insignificant decimal numbers for our purposes. These produce a
misleading level of precision in the display. The factory recommends using a maximum of four digits
regardless of the decimal point position.

Example:

for 60.675, enter 60.67

for 2.3456, enter 2.346

The largest number you can enter as a KFR is 65000, ignoring the decimal point position. A message
alerts you if the number you enter is too large.

2. FT for A (Default 10000)

In order to make the EMO-500 display the correct Totalized Value in Engineering Units, again the most
important thing to know is the K-factor of the flow meter. The K-factor is the relationship between the
amount of the impulses and the engineering units.

To calculate the KFT, apply the following formula:

10000

K-factor

Notice

Notice

KFT =

KFR =

100 is the constant for seconds
6000 is the constant for minutes
360000 is the constant for hours

= 2.921 GPM

KFR =

Advertising