Delmhorst Instrument Navigator User Manual

Page 15

Advertising
background image

Copyright

2007, Delmhorst Instrument Co.

Page 15 of 28

This screen contains the following information: Job # and ID, current location (LOC),
number of records (REC) for the current room, and memory used (MEM).

Rooms are ordered as in APPENDIX A, Floor (F), Wall (W), and then Ceiling (C). Only
locations for which a material was chosen can be selected for measurements.

2. You may begin taking readings by firmly pressing the back of the meter onto the

material.

3. This will display a relative reading that ranges between 0 and 300. Once you are

satisfied with the value indicated for the selected location, press the SELECT key to
store a reading.

4. You will notice the word HOLD in the right hand side of the screen. If you press the

SELECT key again the meter will store that reading and

automatically increment to the

next defined location. (Example: LR, F then LR, W, then LR, C.)

If no storage is desired for this location, manually select a different location by doing the
following:

1. Use the

с т keys to highlight LOC. Press SELECT to get into the LOCATION

definition sub menu.


2. Use the

п р keys to change the location.

Note: You can only scroll through the pre-defined locations and areas as
described above.

3. Select DONE to save your new location; CANCEL to leave the previous location.

TO TAKE PIN READINGS IN ENHANCED MODE

TO SET THE ALARM IN ENHANCED PIN MODE:

1. If you wish to set the alarm to beep after a pre-selected value is reached, use the

ò key

from the ENHANCED main menu, highlight Option 3: SET UP. Press the SELECT key to
enter the SET UP sub menu.


2. Use the

ò key and highlight #6: SET PIN MODE ALARM. You will see a selection of

materials to choose from. Highlight the desired material and press the SELECT key.

Advertising