Delmhorst Instrument Navigator User Manual

Page 8

Advertising
background image

Copyright

2007, Delmhorst Instrument Co.

Page 8 of 28

3. Use the

òkey to highlight the default material (Oak) if you wish to change it to a

different material. Press the SELECT key to get into the SELECT MATERIAL sub menu.

4. Use the

с т keys to highlight the material you are testing. Press the SELECT key to

choose that material. This will bring you back to the main %MC READ screen.

You may begin taking readings by inserting the pins into the material and pressing the
SELECT key. This will display a %MC reading. If you wish to hold a reading on screen,
press the SELECT key again; otherwise remove the pins from the material being tested
and take another reading.

TO SET THE ALARM IN BASIC PIN MODE:

1. If you wish to set the alarm to beep after a pre-selected %MC value is reached, use the

с т keys from the %MC screen to highlight the ALARM. Press the SELECT key to
enter the alarm sub menu.

2. The default status of the alarm is “OFF.” Press the SELECT key to turn it on.

3. After the alarm is turned on, use the

п р keys to scroll up or down to a higher or

lower alarm value.

4. After you have selected the alarm value, use the

òkey to highlight DONE. Press

SELECT to get back to the %MC READ screen.

Default alarm settings in pin mode are as follows for different materials:

All wood materials:

12%

Sheetrock®:

1.0%

Plaster:

68 (on the 0-100 relative scale)

Concrete:

68 (on the 0-100 relative scale)

Note: The default alarm setting in scan mode is 300.