GW Instek GRF-1300A User Manual
Page 12

GRF-1300A User Manual and Teaching Materials
used to adjust the frequency of the baseband signal. The
baseband module is adjustable in 10kHz steps.
• WAVE Select is used to select three different baseband
waveforms. When the waveform is selected, the
corresponding LED light will be lit up.
• The Reset button is used to reset the GRF-1300A. When
reset, the GRF-1300A will output a 0.10MHz sine wave
baseband signal and a carrier signal with a frequency
880MHz.
• The output port is used to output the set baseband signal.
• The four-digit display is used to display the frequency of
the output baseband signal.
• TP4 (test point 4) is used to used to monitor the output
signal from the output port.
• The potentiometer knob is used to adjust the voltage of the
output baseband signal. Turn clockwise to increase the
amplitude and turn anticlockwise to decrease its
amplitude.
Figure A-4.
Baseband module
5. The UP and DOWN buttons on the RF Synthesizer / FM
module can be used to adjust the frequency of the carrier. The
carrier can be adjusted in 1MHz steps.
10