The relationship between db and dbc, Grf-1300a user manual and teaching materials – GW Instek GRF-1300A User Manual
Page 120

GRF-1300A User Manual and Teaching Materials
The relationship between dB and dBc
The figures in the table above are based on a 50Ω load. As an
example, as -30dBm is equal to 0.001mW or 10
-6
W, therefore with
a 50Ω load it is 7071.07 uV or 0.007071mV. The formulas and
derivations from the above table are:
10
10
dBm
inmW
P
=
=>
R
P
V
×
=
=>
)
log(
20
uV
V
dBuV
×
=
further
)
log(
10
mW
P
dBm
×
=
)
log(
20
mV
V
dBmV
×
=
As for dB and dBc, they are relative units. In terms of power, a
difference of 20dB is equal to a difference of 100 times.
Question
What is the difference between 0dBm and-50dBm? Is it 50dB or
50dBm?
Answer
50dB
Explanation
0dBm = 1mW, -50dBm = 10
-5
mW, therefore the difference of both
is 10
5
times which equal to 50dB or a difference of 0.99999mW
And 0.99999mW is equal to -0.0000434dBm ≈ 0dBm.
50dBm = 10
5
mW = 100W. Obviously 50dBm is the wrong
answer.
118