RF Communication and Signals Experiments

Experiment
contents

1. Measure the RF signal spectrum.

2. Measure the harmonic distortion of the RF signal.

3. Measure the phase noise of the RF signal.

Experiment
steps

Measure the RF
signal spectrum
and harmonic
distortion.

1. Turn on the GRF-1300A and GSP-730. Leave the GRF-1300A

in its power-on state.

2. Connect the RF/FM output port on the GRF-1300A to the

input terminal on GSP-730 with the RF cable.

3. Set the GSP-730 as follows:

• Span: Full Span

• Reference level: 0dBm
• RBW: Auto: Auto

Step1

Step2

F1

Step3

BW

F1

4. On the observed spectrum, use the marker function to

measure the amplitude of each frequency point. The Next
peak function can be used to find each consecutive peak. Plot
the results in table 4-1.

Step4

Step5

F2

5. Draw the results in table 4-1. The harmonic ratio of each the

harmonic can be measured according to the following steps.

Step6

Marker

7

6

Step7

Marker

2

6

4