INOR IPAQ C201 GB User Manual

Analog pc-programmable 2-wire transmitter, C201

Advertising
background image

MEASURE OF SUCCESS

USER INSTRUCTIONS

Analog PC-programmable

2-wire Transmitter

for Pt100 Input

The user instruction must be read prior to adjustment and/or installation.

All information subject to change without notice.

86B
C201001 2010-11

GENERAL INFORMATION

IPAQ C201 is an analog, non-isolated, easy-to-use 2-wire

temperature transmitter for Pt100 input intended to be used in

industrial environment.

The transmitter is configured from a PC via a USB port, connected

via the INOR USB Interface, by using the ConSoft program.

Calibration of the transmitter after the PC configuration is not

necessary.

ConSoft is compatible with Windows 2000 (SP3), Windows XP and

Windows Vista (32-bit).

All necessary hardware and software for configuration are included

in the ICON Configuration Kit, 70CFGUS001.

C201

MEASURE OF SUCCESS

This product should not be mixed with other kind of scrap, after usage.

It should be handled as an electronic/electric device.

www.inor.com, www.inor.se

DATA (shortform)

Input Pt100

3-wire connection

Pt100 (

α

=0.00385)

-50 to +850 °C / -58 to +1562 °F

Pt100 (

α

=0.003902)

-50 to +850 °C / -58 to +1562 °F

Pt100 (

α

=0.003916)

-50 to +850 °C / -58 to +1562 °F

Sensor monitoring
Sensor break

Upscale (≥21.0 mA) or downscale (≤3.6 mA)

Sensor short-circuit

Fixed downscale (≤3.6 mA)

Adjustments - Zero -50, -25, 0, +25, +50 °C / -58, -13, +32, +77, +122 °F
Adjustments - Minimum span 20 °C / 36 °F
Output

4-20 mA, temperature linear

Response time

< 50 ms

Ambient temperature

Operation

-40 to +85 °C / -40 to +185 °F

Storage

-50 to +85 °C / -58 to +185 °F

Galvanic isolation

No

Power supply

8.5 to 32 VDC

Accuracy

1)

Max. of ±0.1 °C / ±0.2 °F or ±0.1 % of span

Connection head

DIN B or larger

1)

Includes calibration and linearity errors

CONFIGURATION

Guidelines for ConSoft version 1.1.0.2 or higher.

Before making a configuration of IPAQ C201 you need to do

following:

1. Install the drivers for the INOR USB Interface.

2. Install the PC configuration software ConSoft in your PC.

Please refer to “Installation Guide for ICON”, 86BCONF004, for

detailed installation instructions. All software and guides are included

in the ICON Configuration Kit, 70CFGUS001, and can also be

downloaded from the web site www.inor.com.

Configuration procedure:

The help file in ConSoft contains complete information about the

configuration procedure. Here is a short-form guide:

1. Connect the IPAQ C201 to the PC via the USB Interface.

Configuration can be performed with or without connected power

supply.

2. In ConSoft, click on the upper left “Read from transmitter”

button. The software will automatically recognize the

connected transmitter and open the “C201/R201” configuration

window.

3. In the “C201/R201” configuration window you can enter:

a. Pt100 type (3 different standards)

b. Measuring range in three different engineering units

c. Upscale or downscale action at sensor break

d. Compensation for known sensor errors

e. TAG-number

4. The selected configuration is downloaded to the transmitter by

clicking the button “Transfer to transmitter”. When the transfer

is complete, the transmitter begins using the new parameters

directly.

INOR Process AB, PO Box 9125, SE-200 39 Malmö, Sweden,

Phone: +46-40-31 25 60, Fax: +46-40-31 25 70, E-mail: [email protected]

INOR Transmitter OY, Unikkotie 13, FI-01300 Vantaa, Finland,

Phone:+358-10-421 7900, Fax: +358-10-421 7901, E-mail: [email protected]

INOR Transmitter GmbH, Am Bocksborn 5,

D-63571 Gelnhausen, Germany,

Phone: +49-6051 14807, Fax: +49-6051 14806, E-mail: [email protected]

KROHNE Temperature Division INOR, 7 Dearborn Road,

Peabody, MA 01960, USA,

Phone: +1-978-826 6900, Fax: +1-978-535 3882, E-mail: [email protected]