On fig 2-4 – KEPCO BOP-HV User Manual

Page 25

Advertising
background image

BOPHV 112211

2-5

FIGURE 2-4. REAR PROGRAMMING CONNECTOR WIRED FOR FRONT PANEL OPERATION

B)

Note: The rear sensing links must be attached to the rear terminals of the BOP as shown in
FIG. 2-2 and the rear connector must be attached and secured.

C) Set the BOP front panel controls as follows (refer to FIG. 2-2). The controls will be identi-

fied here and in the following manual text with the nomenclature used in Table 2-2 and
identifying numbers used in FIG. 2-2):

1)

MODE switch (4), set to “VOLTAGE”.

2)

BIPOLAR VOLTAGE CONTROL (10), set switch to "ON", control to its extreme coun-
terclockwise position.

3)

A-C POWER switch to "ON".

D) The indicator lamp, part of the A-C POWER switch (1) will be "ON". The "OUTPUT

READY" lamp (2) AND "E

O

MODE" lamp (12) will also be "ON".

E)

Turn the BIPOLAR VOLTAGE CONTROL (10) clockwise through its range, while observing
the front panel "E

O

METER" (11). The BOP output voltage should smoothly follow from the

maximum negative output voltage, over zero, to the maximum positive output voltage of
the BOP. Turn A-C POWER SWITCH (1) “OFF”.

F)

Connect a short-circuit between the (

±) OUTPUT and the COMMON front panel output ter-

minals (3). Set the BOP front panel controls as follows:

1)

MODE SWITCH (4), set to "CURRENT".

2)

BIPOLAR CURRENT CONTROL (16), set switch to “ON”, control to its maximum
counterclockwise position.

3)

A-C POWER switch "ON".

G) The indicator lamp, part of the A-C POWER switch (1) will be "ON", the "OUTPUT READY"

LAMP (2) and the "I

O

MODE" lamp (18) will be "ON".

Advertising