FIGURE 3-22. PROGRAMMING CIRCUIT FOR DRIVING THE BOP OUTPUT CURRENT WITH A

HIGH IMPEDANCE SOURCE

3.4.2

REMOTE CONTROL OF THE BOP CURRENT LIMIT

The BOP I

O

LIMIT CIRCUIT in the local (front panel) control mode is shown in FIG. 3-23. A (+)

10 volt reference voltage is repeated and inverted to obtain two reference voltages (+10V and -
10V respectively). These references are applied at the input of the two (±) I

O

LIMIT CONTROL

AMPS. Both control amplifiers operate in the inverting configuration and produce the control
potential according to the output equation:

Since “Rf” is adjustable, the control voltage (E

CONTROL

) can be varied from zero to (+)10V and

(-)10V respectively, thus providing output current limit control over the full range of the BOP

Econtrol = (–)

Eref

Ri

----------- Rf