4.4 Connection of the output cable
4.4.1 IP67 housing (compact and field version)
Electrical values
• Pulse output passive:
Pulse output passive:
Pulse output passive:
Pulse output passive:
f ≤ 100 Hz; I ≤ 10 mA; U: 2.7...24 VDC (P ≤ 100 mW)
• Status output passive:
Status output passive:
Status output passive:
Status output passive:
I ≤ 10 mA; U: 2.7...24 VDC (P ≤ 100 mW)
Figure 4-5: Removing side cap
Figure 4-6: Terminal assignment
1 Status output 1 or pulse output C
2 Status output 2
3 Not used
4 Common ground
5 Pulse output A
6 Pulse output B
6
5
4
3
2
1