Technical data – KROHNE WATERFLUX 3070 EN User Manual
Page 70
Advertising

8
TECHNICAL DATA
70
WATERFLUX 3070
www.krohne.com
06/2013 - 4001410205 - HB WATERFLUX 3070 R05 en
MI-001 certified flow characteristics
DN
Span (R)
Q3 / Q1
Flow rate [m
3
/h]
Minimum Q1
Transitional Q2
Permanent Q3
Overload Q4
25
400
0.025
0.040
10
12.5
25
400
0.040
0.064
16
20.0
40
400
0.063
0.100
25
31.3
40
400
0.100
0.160
40
50.0
50
400
0.100
0.160
40
50.0
50
400
0.158
0.252
63
78.8
65
400
0.158
0.252
63
78.8
65
400
0.250
0.400
100
125.0
80
400
0.250
0.400
100
125.0
80
400
0.400
0.640
160
200.0
100
400
0.400
0.640
160
200.0
100
400
0.625
1.000
250
312.5
125
400
0.625
1.000
250
312.5
125
400
1.000
1.600
400
500.0
150
400
1.000
1.600
400
500.0
150
400
1.575
2.520
630
787.5
200
400
1.575
2.520
630
787.5
200
315
2.540
4.060
800
1000.0
250
400
2.500
4.000
1000
1250.0
300
400
4.000
6.400
1600
2000.0
Advertising