ELECTRICAL CONNECTIONS

26

OPTISONIC 6300

www.krohne.com

07/2009 - 7.30959.24.00 - QS OPTISONIC 6300 R04 en

Description of abbreviations and CG identifier for possible optional modules
on terminals A and B

Abbreviation

Identifier for CG No.

Description

I

a

A

Active current output (including HART = HART

®

capability)

I

p

B

Passive current output (including HART = HART

®

capability)

P

a

/ S

a

C

Active pulse, frequency, status output or limit switch (changeable)

P

p

/ S

p

E

Passive pulse, frequency, status output or limit switch (changeable)

P

N

/ S

N

F

Passive pulse, frequency, status output or limit switch according to

NAMUR (changeable)

C

a

G

Active control input

C

p

K

Passive control input

C

N

H

Active control input to NAMUR

Signal converter monitors cable breaks and short circuits as per EN

60947-5-6. Errors indicated on LCD display. Error messages possible via

status output.

IIn

a

P

Active current input

IIn

p

R

Passive current input

-

8

No additional module installed

-

0

No further module possible

.book Page 26 Wednesday, August 19, 2009 8:37 AM