• Loosen the lock screw with a 2.5 mm Allen wrench.
• Turn the cover counterclockwise with a strap wrench.
• Remove the cover.
Equipment needed:
• Small slotted tip screwdriver (not supplied)
Procedure:
1 Do not disconnect the safety cord from the terminal compartment cover. Put the terminal
compartment cover adjacent to the housing.
2 Remove the connector from the circuit board.
3 Connect the electrical wires to the connector. Attach the connector to the circuit board. Tight-
en the cable entry glands.
• Put the cover on the housing and push it down.
• Turn the cover clockwise until it is fully engaged.
• Tighten the lock screw.
Figure 3-3: Procedure for electrical installation
Close the terminal compartment cover
Figure 3-4: How to close the terminal compartment cover