Electrical connections – KROHNE OPTISENS MAC 080 EN User Manual
Page 21

ELECTRICAL CONNECTIONS
4
21
OPTISENS MAC 080
www.krohne.com
01/2010 - MA MAC 080 R02 en
4.3.1 Analog outputs
The two analog outputs of the converter are default active, sourcing 4...20 mA into a load of
maximum 450 Ω. They are galvanic isolated from the rest of the system, but the two channels
use a common ground.
Channel 2 can be jumpered to be passive, and fully isolated sink 4...20 mA from an external
supply of max. 24 VDC, by changing JP1 and JP7.
Analog output channel 2
Position JP1
Position JP7
Active, sourcing (default)
1-3 and 2-4
1-2
Passive, sinking
1-2 and 3-4
3-4
Figure 4-3: Active analog output (channel 1 or channel 2)
1 External load passive
2 Converter terminal 6 or 8
3 Converter active sourcing 4...20 mA
4 Converter terminal 7 or 9
Figure 4-4: Passive analog output (channel 2 only)
1 External load
2 External 24 VDC
3 Converter terminal 8
4 Converter passive sinking 4...20 mA (channel 2 only)
5 Converter terminal 9
.book Page 21 Tuesday, January 19, 2010 1:07 PM