Electrical connection
General
Electrical connection is carried out in conformity with the VDE 0100 directive
"Regulations for electrical power installations with line voltages up to 1000 V" or
equivalent national specifications.
Power supply
100…230 VAC (-15% / +10%), 50/60 Hz;
240 VAC + 5% is included in the tolerance range.
24 VDC (-30% / +30%)
Power consumption
AC: 15 VA
DC: 5.6 W
Signal cable
Only necessary for remote versions.
DS 300 (type A)
DS 300 (type A)
DS 300 (type A)
DS 300 (type A)
Max. length: 600 m / 1950 ft (depending on electrical conductivity and measuring
sensor version)
Cable entries
Standard: M20 x 1.5 (8...12 mm)
Option: ½ NPT, PF ½
Outputs
Basic
All outputs are electrically isolated from each other and from all other circuits.
All operating data and output values can be adjusted.
Description of abbreviations
U
ext
= external voltage; R
L
= load + resistance;
U
o
= terminal voltage; I
nom
= nominal current