KROHNE OPTIMASS with MFC 300 EN User Manual

Page 37

Advertising
background image

37

OPTIMASS

6

OPTIMASS 3000

6.1 Specific Installation Guidelines

The OPTIMASS 3000 is a single Z Shaped Tube Meter. During installation, the following general
guidelines MUST be followed:

•

The base plate has four holes to enable the meter to be mounted and all four mounting
holes MUST be used

•

The plastic inserts in the base plate mounting holes are important to ensure a rigid and sta-
ble connection to the mounting structure.

•

It is important to mount on a firm and rigid structure to obtain a stable zero condition.

•

The following guidelines are provided to assist the installer to select the best option:

Orientation:

The meter can be mounted horizontally or vertically

If mounting vertically the meter MUST be mounted with the flow uphill and with a set angle
from the vertical that allows the meter to self drain The set angles are:

DO NOT allow the pipework to carry the weight of the meter This
will cause severe damage!

DO NOT mount the meter upside down!

Meter Size

Angle of Rotation (Clockwise)

01

7°

03

13°

04

13°

1

Horizontal Mount

2

7° clockwise rotation from the vertical. (See angle markings on base plate).

3

13° clockwise rotation from the vertical. (See angle markings on base plate).

1

2

3

Advertising