KROHNE OPTIMASS with MFC 05x EN User Manual
Page 20

Installation and Operating Instructions OPTIMASS
19
1.2.9 Technical Data
Nominal Flow Rates
06
10
15 25 40 50
80
Kg/h
950 2,700 11,250 34,500 91,500 180,000 430,000
Lbs/min
35 100 400
1,250 3,350 6,600
15,800
Maximum flow rate
Typically 130 % of the nominal flow rate for the sensor size depending on application.
Minimum flow rate
Depending on measuring error required.
Tube materials:
•
Titanium Gr. 9,
•
Hastelloy C22 and
•
SS 318.
The meter size has a prefix T, H, or S indicating the tube material.
Secondary pressure containment
•
All 70 Series meters have secondary containment rated to 40 bar or 580 psi.
•
An optional 63 bar or 914 psi is available.
Materials of construction
•
Flanges: SS 316 L
•
Spigots and outer cylinder: SS 304 L optional SS 316 L
•
Front end housing and post: SS 316 L
•
Converter housing: Epoxy coated aluminium