4.5 Reset / Quit Menu - Totalizer reset and status indication acknowledgement


Totalizer reset

Button Display

Description

10.36

kg

Measurement mode

↵

CodE 2
––

Enter access Code 2 for reset/quit menu:

↑ →

↑ →

RESET.TOTAL

Totalizer reset menu

If the additional totaliser is selected (Fct. 3.1.6) a choice of reset
options is presented:
* RESET ALL

Reset all totalisers

* ADDITIONAL

Reset only the additional totaliser


Otherwise the following is presented:
* SURE YES
* SURE NO

Note:

The reset option can be disabled by Fct. 3.5.3 or Custody

Transfer (CT) lock.


View status message(s) and quit

Button Display

Description

0.36

kg/min

∇

Measurement mode
The presence of the

∇ marker above Status on the display

indicates the presence of warning messages in the status list.

↵

CodeE 2
– –
∇

Enter access code for reset/quit menu:

↑ →

↑→

RESET.TOTAL

∇

Totalizer reset menu.

↑

STATUS.LIST

∇

View/Quit Status message menu

→

MASS FLOW

∇

Use either the

↑ or → keys to view other messages in the list.

Otherwise press

↵ to exit.

→


QUIT YES

∇

At the end of the message list the QUIT YES prompt is shown.
Selecting YES will clear if possible messages in the list.
To cancel the operation press

↑ to get QUIT NO and then press

↵.

↵

STATUS.LIST

Assuming the conditions that caused the message have passed
(i.e. mass flow is back within the meter’s range) then the Status
marker,

∇ will disappear.

↵

Returns to measuring mode.


An overview with typical status messages and descriptions will be given in the table in chapter 6.2.

View FE Status

Button Display

Description

↵

CodeE 2
– –

Enter access code for reset/quit menu:

↑ →


↑
↑

RESET.TOTAL
STATUS.LIST
FE STATUS

Totalizer reset menu.
View/Quit Status message menu
View FE Status messages

→

Messages

Normally no messages are present.
Further messages are sometimes present which indicate the
various diagnostic indicators, primarily for service or trouble
shooting purposes.