KROHNE OPTIMASS with MFC 05x EN User Manual

Page 92

Advertising
background image

Installation and Operating Instructions OPTIMASS

91

5.5 Menu 5 - Factory Settings

This menu allows the user to view certain information relating to the meter. E.g. calibration co-efficients,

meter type, size, serial numbers etc.


Fct. 5.1.1. through to Fct. 5.1.20. Read only transducer co-efficients.

Meter Corr. Fct. 5.1.21.

Correction factor if meter over or under reads in an application.

If under reading, add the required value in + percent in this menu.

If over reading, deduct the required percentage i.e. change sign to – and program the percentage error.


Meter (sensor) description and settings – Menu 5.2

From this menu the relevant data concerning the sensor is stored.


Meter Type Fct. 5.2.1.

Displays the meter type.
•

OPTIMASS 7000. Single Straight Tube meter.

•

OPTIMASS 3000. Single bent tube low flow meter. (7100)

•

OPTIMASS 8000. Dual U-tube meter (Max 230°C)

•

OPTIMASS 9000. Dual U-tube meter (Max 350°C)

•

OPTIGAS 5000. Dual Omega tube for CNG filling stations


Meter Size Fct. 5.2.2.
•

If OPTIMASS 7000 is displayed in Fct. 5.2.1. then one of the following sizes will be displayed (See

tech. datasheet for flow rates etc): 06; 10; 15; 25; 40; 50; 80.

•

If OPTIMASS 3000 is displayed in Fct. 5.2.1. then one of the following sizes will be displayed:

01; 03; 04.

•

If OPTIMASS 8000 or 9000 is displayed in Fct. 5.2.1. then one of the following sizes will be displayed:

15; 25; 40; 80; 100.

•

If OPTIGAS 8000 or 9000 is displayed in Fct. 5.2.1. then one of the following sizes will be displayed:

15; 25.


Material Fct. 5.2.3.

Displays the measuring tube material of the meter.
•

OPTIMASS 7000. One of the following: Titanium, Hastelloy, Stainless Steel.

•

OPTIMASS 3000. One of the following: Stainless Steel, Hastelloy.

•

OPTIMASS 8000/9000. One of the following: Stainless Steel, Hastelloy, Titanium

•

OPTIGAS 5000. Stainless Steel


Tube Amp. Fct. 5.2.4.

Displays the set tube amplitude in percent.


Temperature Limits – Menu 5.3

Fct. 5.3.1 and Fct. 5.3.2 displays the maximum and minimum allowable process temperatures the meter

may be used for.


Temperature History – Menu 5.4

This menu allows the viewing of the maximum and minimum recorded temperature the meter has been

exposed to.
•

Menu 5.4.1 is the maximum temperature.

•

Menu 5.4.2 is the minimum temperature.