KROHNE CARGOMASTER User Manual

Page 32

Advertising
background image

CARGOMASTER®5

Operators Manual - 32

For tank groups:

From ValueTable (Alt+F3) select the Alarm layer tab. Enter a new value in the
Sum cell for the appropriate column. Or:

From Loading (F2) in the Group menu, select the Alarm tab and enter new
value to adjust. Clicking the More Alarms button will bring up more detailed
alarms.

From Seagoing (Alt+F2) or Discharge (Shift+F2) in the Group menu enter
new value to adjust

Note: Altering an alarm limit will not set the alarm to on or off status

Alarms on - off

Depending on alarm types, there are several ways to turn alarms on or off, or
adjust the limits:

For single tanks:

Click the tank in Tank Plan (Shift-F3); select the Alarm tab and
check/uncheck the alarm.

Or:

From ValueTable (Alt-F3) select the Alarm On/Off layer tab. Type on or off
in the appropriate cell.

For tank groups:

From ValueTable (Alt-F3) select the Alarm On/Off layer tab. Type on or off
in the Sum field for the appropriate column.

Or:

From Loading (F2), select the Alarms tab. Check / uncheck alarms to turn on
or off. The More Alarms button will display more detailed alarms.

From Seagoing (Alt-F2) or Discharge (Shift-F2) in the Group menu check or
uncheck the alarms to turn on or off

Available Alarm Types

The following alarms can be set:

Alarm code

Alarm name

Default limit

HHL

High High Level

98%

HIL High

Level 95%

LOL Low

Level 5%

LLL

Low Low Level

3%

HIT

High Temperature

50 deg Celcius

LOT

Low Temperature

0 deg Celcius

Advertising