NSi Industries DIN100B User Manual

Din100b, One channel digital timer, Programming the timer

Advertising
background image

MODEL#:

DIN100B

DIGITAL CONTROL

INPUT VOLTAGE:

120VAC 50/60Hz, 4VA

CONTACT CONFIGURATION:

Dry Contact SPDT

SWITCH RATING:

16A 120VAC Resistive, 8A 120VAC General Purpose, 1/2HP @120VAC

NUMBERS OF EVENTS:

8 ON/OFFs

IMPORTANT SAFETY INSTRUCTIONS

READ & FOLLOW ALL INSTRUCTIONS – SAVE THESE INSTRUCTIONS

ATTENTION: Read carefully before attempting to install this control. Failure to comply with instructions could result in personal injury and/or property damage!

This control must be installed in accordance with National and Local Electrical Codes. Disconnect power at main panel before installing or servicing this device.

Do not exceed the ratings of this device, and current capacity of conductors. This control should not operate any equipment which would cause bodily injury or

property damage should it be activate unexpectedly.

BATTERY INSTRUCTIONS

The lithium battery inside timers will be covered by a very thin insulation film which should be

removed while/after installation

PROGRAMMING THE TIMER

KEYPAD FUNCTIONS DESCRIPTION:

TIMER:

To set/review/modify events. MANUAL: Changes the load

control to either ON, AUTO, or OFF.

CLOCK:

To enable clock set and exit programming. DAY: To set the

day(s). HOUR: To set hour. MIN: To set minute.

RESET:

Resets the timer and clears all memory.

SETTING THE CLOCK: Press and hold CLOCK button and then

press DAY, HOUR, and MIN buttons to set the current time and day-of-

the-week.

PROGRAMMING SCHEDULE:

NOTE: Please press the RESET button prior to installation and initial

programming.

1: Press TIMER button: This is the first ON event. The LCD should show:

2: Press DAY button to select the desired day-of-the-week setting. Each

press advances the selection for each of the possible 15 daily combi-

nations.

1. MO TU WE TH FR SA SU

2. MO

3. TU

4. WE

5. TH

6. FR

7. SA

8. SU

9. MO TU WE TH FR

10. SA SU

11. MO TU WE TH FR SA

12. MO TU WE

13. TH FR SA SU

14. MO

WE FR

15. TU TH SA

3: Press HOUR and MIN buttons respectively to set the event time.

4: Press the TIMER button to store this event, and advance to the next

event, the first OFF event. The LCD should show:

5: The unit will alternate ON and OFF events every time you press the

TIMER button. Repeat steps 2-4 for each required event.

After you’ve finished programming the timer, press CLOCK button to

exit programming mode.

TO REVIEW/MODIFY PROGRAMS: Press TIMER button. Each

time you press the TIMER button you advance between alternate ON

and OFF events, numbered 1 to 8 and then back to 1. Modify events

as needed by using DAY, MIN, and HOUR buttons as before. Press

TIMER button to store the changes and advance to the next event.

OVERRIDE: In the AUTO mode, you can turn the load either ON

or OFF by pressing MANUAL button. Using the same button you can

return back to the AUTO mode to resume schedules.

LOAD STATUS INDICATORS: There is an LED, marked “Power”

to indicate current load status.

RANDOM SCHEDULES OVERRIDE: To execute a random sched-

ule (ON and OFF time varies in a random pattern every 10 to 120

minutes) press and hold DAY button then press MIN button. While in

the Random mode, the LCD will display the following symbol:

To return to normal schedules, press and hold DAY button, then press

MIN button.

TORK, INC. • 888.500.4598 • www.TORK.com

®

ONE CHANNEL DIGITAL TIMER

A DIVISION OF

NSi INDUSTRIES, LLC

E315214

OFF

- - : - -

_

ON

- - : - -

_ _

LI-797(A)