NSi Industries EJWT User Manual

Ejwt, Percentage timer, Installation & wiring instructions

Advertising
background image

MODEL#:

EJWT

The control will cycle loads on/off based on the setting of the control knobs as long as input power is supplied. The control will start with the on time cycle after initial power is applied

to the control. The unit is simple to set consisting of only two dials: one CYCLE TIME dial to set time durations and one % ON dial to set the percentage of ON time for the selected

duration.

Total cycle duration can be set from 15 seconds minimum to 24 hours maximum, The % ON setting for each cycle duration is independently adjustable from 0% (continuous OFF) to

100% (continuous ON) in 32 increments
POwEr

rEquirEMEnts:

Inputs: 120 and 240 VAC (+10% -15% at 60 Hz)

Outputs: SPDT relay with 20 Amp N.O. and 10 Amp N.C. general purpose at 120,240 VAC; N.O. 1 HP at 120 VAC, 2HP at 240 VAC

EnvirOnMEntaL:

Operating Temperature Range: 32°F to 122°F (0°C to 50°C).

Operating Humidity Range: Relative humidity up to 100%

Water Resistance: The control will be capable of direct low-pressure water wash down according to NEMA 4X specification.

COntaCt

ratinG:

EnCLOsurE:

NEMA type 4X (indoor use only) enclosure standard (EJWT). Watertight cover with gasket is flame retardant UV stabilized and non-metallic. In grey.

MOuntinG:

Control is compatible for mounting to Tork’s NEMA 4X nonmetallic enclosure

DiaLs:

Sealed from external access

MaintEnanCE:

Cleaning: Use only mild detergent and water

to clean the enclosure

INSTALLATION & WIRING INSTRUCTIONS

Note:Wiring connections are made to a six-position terminal block. All

terminals accept AWG #18 to AWG #12 wire.

1. Turn off all power to the timer circuit at the distribution panel before

beginning the installation.

2. The EJWT box contains knockouts on two sides. Determine the most

convenient way to mount the box to the conduit and remove the

appropriate knockout. To secure the box to a fixed location, use at

least two of the four box mounting knockouts located on the back of

the box.

3. Wire timer for either 120 VAC or 240 VAC as shown by the wiring

diagram. Wire the load to the timer as shown in the wiring diagram,

noting the contact load type and ratings shown.

4. Securely attach the timer to Tork’s NEMA 4X (for indoor use only)

non-metallic enclosure with the included screws.

®

PERCENTAGE TIMER

VOLTAGE

LOAD TYPE

N.O. CONTACTS

N.C. CONTACTS

120-240 VAC

Resistive

20 A

10 A

120-240 VAC

General Purpose

20 A

10 A

120 VAC

Motor

1 HP

¼ HP

208-240 VAC

Motor

2 HP

½ HP

120-240 VAC

Pilot Duty

470 VA

275 VA

! CAUTION !

RISK OF ELECTRIC ShOCK

Disconnect power at main panel prior to installing

or servicing this lighting control or the equipment connected to it.

T

LOAD

NC

NO

COM

240V/L1

120V NEUT/L2

120V

FOR 240V

L2

L1

120V

L

N

APPLY ONLY ONE VOLTAGE

SPDT

L1

L2

FOR 240V

N

L