Ppp/max failure, Connection list/dial out, Dial out/number 1 – ADTRAN Express 4100 User Manual

Page 99: Dial out/number 2, Dial out/call type, Ppp/max failure -49, Connection list/dial out -49

Advertising
background image

Chapter 3. Terminal Menu Operation and Structure

61200176L2-1

Express 4100/4110 User Manual

3-49

PPP/Max Failure

Write security: 3; Read security: 5

Due to the nature of PPP, configuration options may not be agreed upon
between two PPP peers. This value is the number of configuration-naks
that should occur before an option is configuration-rejected. This allows
a connection to succeed that might otherwise fail. The possible values are
5 (def), 10, 15 and 20.

Connection List/Dial Out

The dialing parameters for establishing this connection are defined under
this menu.

Dial Out/Number 1

Write security: 3; Read security: 5

This is the first number used for dialing up this connection.

Dial Out/Number 2

Write security: 3; Read security: 5

This is the second number used for dialing a second B-channel when
adding bandwidth. If BACP/BAP is negotiated, this number is not nec-
essary. If this number is not specified and BACP/BAP is not used, the
Number 1

number is re-dialed when adding bandwidth.

Dial Out/Call Type

Write security: 3; Read security: 5

The call type can be configured in four different ways:

Speech

Speech directs the call control software to request a
Mu-law encoded speech circuit as the bearer capabil-
ity for the outgoing calls. The speech option is used
with an ISDN line configured for voice service. In
some areas, voice service costs less than data ser-
vices. A speech call type does not always guarantee
an end-to-end digital connection with some local and
long distance carriers.