Installation Manual

Removing an Integral Endpoint from the Assembly Housing

MPORTANT

I

Removing the endpoint from the assembly housing can only be done once. Once removed, the endpoint cannot be

reassembled into an integral configuration with the encoder .

PRIOR TO DISASSEMBLING AN INTEGRAL ENDPOINT, VERIFY THAT THE ENDPOINT HAS THREE FEET OF WIRE

PACKAGED WITH THE ASSEMBLY. CHECK THE SERIAL NUMBER LABEL ON THE SIDE OF THE INTEGRAL BRACKET

TO MAKE SURE IT INDICATES “3 FT WIRE.” DO NOT CONTINUE WITH THE STEPS LISTED BELOW IF YOUR INTEGRAL

ENDPOINT DOES NOT HAVE THIS DESCRIPTION ON THE SERIAL NUMBER LABEL, AS ENDPOINT DAMAGE WILL OCCUR.

1 . Remove the assembly from the meter .

Remove the security screw at the base of

the assembly .

NOTE:

N

Make sure to retain the security screw

for remounting the encoder assembly in

Step 5 .

Turn the endpoint encoder assembly (as one

piece) 1/4 turn, counter-clockwise .

Lift the assembly off the meter .

Figure 28: Remove assembly from meter

2 . Remove the endpoint wire under the

breakaway plate .

Turn the endpoint/encoder assembly over .

Grasp the pull tab located to the right of the

encoder seal screw with pliers (

Figure 29

) . Then

pull and remove the bottom breakaway plate

from the housing to expose the wire . The plate is

scored to facilitate removal .

With your fingers, remove the three feet of

endpoint wire from the housing .

NOTE:

N

The wire is attached to the endpoint .

Figure 29: Pull tab to remove the breakaway plate

Page 29

June 2014