Programming, Programming 9, Mportant i – Badger Meter Test Equipment User Manual

Page 9

Advertising
background image

PROGRAMMING

MPORTANT

I

You must connect terminals 1 and 5 together to enable the programming mode. After all programming is complete, remove the

connection between terminals 1 and 5 to prevent the unit from being reprogrammed by mistake.

To access the programming screens, press and hold the

key while repeatedly pressing the

key until the Program

Mode (1 through 6) you want displays on the screen

1 01.000

Mode 1: Totalizer Scaler lets you enter the count scale factor The far right digit will be flashing
1 Press

to select a digit value or press and hold

to scroll through the numbers

2 Press

to move the flashing digit one place to the left

3 Press

to change the value of the digit

4 Repeat this process until all digits are set correctly

NOTE:

N

Setting the count scale factor to 00 0000 allows scaling by 100 in the ER-Series

2 000000

Mode 2: Totalizer Decimal Point lets you enter the decimal point display on the totalizer screen
1 Press and hold

and then press

to move from screen one to screen two

2 Press

to move the decimal point to the new position

3 0000

Mode 3: Rate Scale Factor display shows the lowercase letter d on the right when it is time to

enter the decimal point position for the rate scaler

OTE:

N

This decimal point is used for the rate scaler only and will not appear on the ratemeter

screen

1 Press

to change the first digit to a new value

2 Press

to select the next digit to be changed

3 Repeat this process until all the digits are correct
4 When the d displays, press

to move the decimal point to another position

4 0000

Mode 4: Rate Scale Factor Decimal Point lets you enter the decimal point position for the

ratemeter run-mode display The display shows the Program Mode number (4) and four zeros

Press

to move the decimal point to another position

5 1

Mode 5: Rate x1/x10 selects the Rate Display Multiplier of one or ten Selecting rate x10 adds a

zero to the far right of the display This zero will not change value and does not affect the decimal

point The display shows the Program Mode number (5) at the left and a 1 at the right

Press

to select 1 or 10

6 r

Mode 6: Reset Key Enable/Disable determines if the front panel Reset key will function The

display shows the Program Mode number 6 on the left and the lowercase letter r on the right
1 Press

to select an option (R=Reset, NoR=Non-Reset)

OTE:

N

The Reset (RST) terminal on the rear panel is still active when the front panel Reset

function is disabled

2 To exit the programming mode, remove the connection between terminals 1 and 5

User Manual

Page 9

September 2013

Advertising