Installation

All Badger Meter Model 1100 turbine meters use stainless steel and tungsten carbide construction materials . Make sure the

operating fluid is compatible with these materials . Incompatible fluids can cause deterioration of internal components and

cause a reduction in meter accuracy .
The measured liquid should be free of any large particles that may inhibit rotation of the turbine blades . If particles are

present, install a mesh strainer upstream before operating the flow meter . See

Table 1

for strainer recommendations .

Part Number

Strainer Mesh

Clearance

Filter Size

B110-375

60 x 60

0 .0092 in .

260 μm

B110-500

60 x 60

0 .0092 in .

260 μm

B110-750

60 x 60

0 .0092 in .

260 μm

B110-875

60 x 60

0 .0092 in .

260 μm

B111-110

60 x 60

0 .0092 in .

260 μm

B111-115

20 x 20

0 .0340 in .

0 .86 mm

B111-120

10 x 10

0 .0650 in .

1 .6 mm

B111-121

20 x 20

0 .0340 in .

0 .86 mm

B111-130, B117-130

8 x 8

0 .0900 in .

2 .3 mm

B111-140, B117-140

10 x 10

0 .0650 in .

1 .6 mm

B111-160

4 x 4

0 .1875 in .

4 .8 mm

B111-180

8 x 8

0 .0900 in .

2 .3 mm

B111-200

4 x 4

0 .1875 in .

4 .8 mm

Table 1: Strainer mesh installation details

The preferred plumbing setup is one containing a bypass line (see

Figure 3

) that allows meter inspection and repair without

interrupting flow . If a bypass line is not used, it is important that all control valves be located downstream of

the flow meter (see

Figure 4

) .

STRIKING AN EMPTY METER WITH HIGH VELOCITY FLOW STREAM CAN CAUSES DAMAGE.

ATTENTION

DES DOMMAGES PEUVENT ÊTRE PROVOQUÉS EN FRAPPANT UN MÈTRE VIDE AVEC UN JET D’ÉCOULEMENT DE VITESSE

ÉLEVÉE.
This is true with any restriction in the flow line that may cause the liquid to flash . If necessary, install air eliminators to ensure

that the meter is not incorrectly measuring entrained air or gas .
Badger Meter recommends installation of a minimum length, equal to ten (10) pipe diameters of straight pipe on the

upstream side and five (5) diameters on the downstream side of the flow meter . Otherwise, meter accuracy may be affected .

Piping should be the same size as the meter bore or threaded port size .
Severe pulsation and mechanical vibration affect accuracy and shorten the life of the meter . If this condition is present,

consider using a flow meter possessing superior resistance to pulsation and vibration like the Badger Meter QuicSert . Do not

locate the flow meter or connection cable close to electric motors, transformers, sparking devices, high voltage lines, or place

connecting cable in conduit with wires furnishing power for such devices . These devices can induce false signals in the flow

meter coil or cable, causing the meter to read inaccurately .
If problems arise with the flow meter, consult the

Troubleshooting Guide on page 11

. If further problems arise, consult

the factory .
If damaged replace the internal components of the turbine flow meter with a turbine meter repair kit available from

Badger Meter . For information pertaining to the repair kits, see

Turbine Replacement on page 8

.