Troubleshooting guide, Part number information, Replacement parts – Badger Meter B2800 User Manual

Page 20: Troubleshooting guide 20, Part number information 20, Replacement parts 20, B 28 a x x - c s

Advertising
background image

TROUBLESHOOTING GUIDE

Trouble

Remedy

No LCD Display

• Check battery voltage Should be 1 5V DC Replace if low or dead

No Rate or Total

Displayed

• Check connection from meter pickup to display input terminals
• Check turbine meter rotor for debris Rotor should spin freely
• Check programming of flow monitor

Flow Rate Display

Interprets Reading

Constantly

• This is usually an indication of external noise Keep all AC wires separate from DC wires
• Check for large motors close to the meter pickup
• Check for radio antenna in close proximity
• Try disconnecting the pickup from the monitor pig tail This should stop the noise

Flow Rate Indicator

Bounces

• This usually indicates a weak signal Replace pickup and/or check all connections
• Examine K factor

PART NUMBER INFORMATION

B 28 A X X - C S

Power Option

B - Battery

L - Loop

Program Level

A - Advanced

Mounting Style

M - Meter Mount

R - Remote Mount

S - Swivel Mount

H - Hand-Held

Units of Measure

CS - Customer Selectable

REPLACEMENT PARTS

Component

Part Number

Keypad

B260713

Battery

B280601

Battery Tie Wrap

B228036

Pickup Cable

B222-121

Desiccant Bag

B260630

PVC Union

B220016

PVC Reducer Bushing

B220056

Rubber Washer

B228207

Steel Lock Washer

B220018

PCB Shield (battery units)

B280603

Desiccant Shield

B280680

Cord Grip

B220103

Flow Monitor, B2800 Flow Monitor – Advanced