Programming, Operation, Requirements – Badger Meter Converters User Manual

Page 3: 95 or newer operating system • dc power supply

Advertising
background image

Operation

OPERATION

Once power is applied, the converter outputs an analog value representative of the measured frequency from the turbine meter.

See

Figure 6

or

Figure 7

—whichever corresponds to the converter that you have selected for your application.

3

2

1

4

5

(BLACK) - Loop
(WHITE) N.C.

(RED) + Loop

3

4

5

2

1

CABLE

CONNECTOR

CONVERTER

MALE CONNECTOR

+ 4…20 mA

- 4…20 mA

+ 4…20 mA (Sink)
- 4…20 mA (Source)

N.C.
N.C.
N.C.

PIN 3
PIN 4
PIN 5

PIN 2

PIN 1

No Connection

RED
BLACK
WHITE

B220952-15 15 FT.

CABLE ASSEMBLY

B220952-6 6 FT.

Figure 6: Frequency to current output wiring

(BLACK) SIGNAL
(WHITE) 0V

(RED) 10…30V DC

B220952-15 15 FT.

CABLE ASSEMBLY

B220952-6 6 FT.

3

4

5

2

1

2

1

4

5

3

CABLE

CONNECTOR

CONVERTER

MALE CONNECTOR

10…30V DC
SIGNAL

10…30V DC
SIGNAL
GND
N.C.
N.C.

PIN 3
PIN 4
PIN 5

PIN 2

PIN 1

0 V

RED
BLACK
WHITE

Figure 7: Frequency to Voltage output wiring

OTEE:

N

If your active sensor was purchased with a Blancett turbine meter, the two components ship from the factory calibrated as

a set. If the active sensor is a replacement, the turbine’s K factor has changed, or the sensor is being used with some other

pulse-generating device, programming is necessary.

PROGRAMMING

OTEE:

N

For complete instructions on programming the Blancett intelligent converters see the IFC Programming Manual.

Requirements

Sensor/Transducer IFC programming kit PN B220-953

RS232 cable (connects programming cable to PC)

IBM Compatible PC running Windows

®

95 or newer operating system

DC Power Supply

Cable Assembly

Blancett P.N. 6558

Active Sensor

RS

-232

TTL

RS-232 T

O TTL

Con

ver

ter

Model 232LPT

TL

TTL to RS232

Converter

Cable To

Computer

(BLACK) SIGNAL
(WHITE) 0V

(RED) 10…28V DC

Cable Assembly

B220952-6 6 ft.

B220952-15 15 ft.

Figure 8: 6558 programming cable connections

OTEE:

N

The TTL-to-RS232 converter may be as shown in

Figure 8

or it may be a black molded model.

Page 3

July 2014

SEN-UM-00084-EN-02

Advertising