Configuration, Configuration 10 – Badger Meter K-Factor Scaler User Manual

Page 10

Advertising
background image

Status: Com1

9/23/2008

File Options Tools

Program Values

Board Values

Program

Read

Verify

Status: Idle

Com Port 1

Pulse Output

High
Low

K-Factor

Pulse Width

150us

Auto

1s

500ms

100ms

25ms

1ms

Pulse Output

High
Low

K-Factor

Pulse Width

150us

Auto

1s

500ms

100ms

25ms

1ms

File

Tools Version

Program
Read
Verify
Com Port

Blancett K-Factor Programming Software

Status: Com1

9/23/2008

File Options Tools

Program Values

Board Values

Program

Read

Verify

Status: Idle

Com Port 1

Pulse Output

High
Low

K-Factor

Pulse Width

150us

Auto

1s

500ms

100ms

25ms

1ms

Pulse Output

High
Low

K-Factor

Pulse Width

150us

Auto

1s

500ms

100ms

25ms

1ms

File

Tools Version

Blancett K-Factor Programming Software

Com 1
Com 2
Com 3
Com 4
Com 5
Com 6
Com 7
Com 8
Com 9
Com 10
Com 11
Com 12
Com 13
Com 14
Com 15
Com 16

Program
Read
Verify

Com Port

Figure 6: Tools drop down

Figure 7: Com port choice drop down

If the serial port selected is invalid, the software will show the message ERROR – Invalid Com Port when trying to program

the board If the serial port selected is the incorrect port (or if there is a problem with the cable), the software will show the

message << No Response >> after trying to program the board

NOTE:

N

All information under in the Program Values column is required before the software allows the downloading

of information

Pressing Program downloads the K factor, pulse width and pulse output values to the K Factor Scaler At the completion of

the programming cycle, the circuit performs automatic verification of the downloaded information If disconnected from the

power the K Factor Scaler retains downloaded values in memory
Pressing Read loads the current information from the K Factor Scaler and displays it in the Board Values column of the

PC software
Verify performs the same function as Read, but compares the Board Values to the Program Values and displays an error if the

two do not match

Configuration

Configuring the K Factor Scaler consists of the following four items:

1 Setting the K factor (divider)
2 Setting the output pulse width
3 Setting the pulse output level normally high or normally low
4 Setting the output pulse to use the internal or external pullup resistor

Signal Conditioner, B220-885 K Factor Scaler and B220-900 Programming Software Kit

Page 10

November 2013

Advertising