Startup, Using optional programming software kit b220-900, Startup 9 – Badger Meter K-Factor Scaler User Manual

Page 9: Using optional programming software kit b220-900 9, Current draw = 0.25 watts external pullup resistor

Advertising
background image

To determine the maximum current available using a specific pullup resistor use the following equation

Current Draw =

0.25 Watts

External Pullup Resistor

STARTUP

Using Optional Programming Software Kit B220-900

(Software sold separately)
The programmable K Factor Scaler can be factory or user configured through a serial port of a PC by a Windows compatible

software utility A programming adapter is required that interfaces the serial port from the PC to the programming port on

the board
To program the K Factor Scaler:

1 Begin with the power turned off and connect the adapter cable to the K Factor Scaler board using the programming

port (see

Figure 2)

2 Connect the serial-to-TTL converter to the adapter cable See

Figure 5

3 Attach the serial extension cable to the serial-to-TTL converter and connect the opposite end to an available nine-pin

serial port of a PC

NOTE:

N

For computers without a 9-pin serial connection a serial to USB converter may be required

4 Turn on the power to the K Factor Scaler

NOTE:

N

Power to the K Factor Scaler is required in order to perform any programming

1

2

3

4

5

6

- OUTPUT

+ OUTPUT

- VIN

+ VIN

8.5 - 30 VDC

TURBINE

PICK UP

INTERNAL

3.6K PULL-UP

RESISTOR

JUMPER

PROGRAMMING

PORT

Racine, WI

U.S.A.

K-FACTOR SCALER

INPUT 8.5 - 30 VDC

MAX INPUT CURRENT: 18 mA

®

C US

FILE #215035

B220-886

Flow Meters

1

2

3

4

5

6

RS-232

TTL

RS-232T

OTTL

Converter

Model 232LPTTL

LOGIC

RS232

Serial Interface Converter

OR

Figure 5: Interface connection

The programming interface uses two functional divisions as shown in

Figure 8

The Program Values column contains the

user-selected information for downloading into the K Factor Scaler The Board Values column shows the information that the

K Factor Scaler currently contains and is not alterable by the user The Board Values column will only display the contents of

the board after performing a Program, Read or Verify function
Selection of the proper computer serial port within the Blancett K Factor programming software is required for it to

communicate with the board From the menu bar, select Tools and then Com Port Select the com port (1…16) that the serial

programming cable is connected to on the computer

User Manual

Page 9

November 2013

Advertising