Blank table into which data my be written for ref, K factor and f/v data edit curve, Analogue input card edit curves – Badger Meter 4050 Flow Computers User Manual

Page 10: Set viscosity/ set s.g, Sort curve and vis temp etc

Advertising
background image

4050 Multi-Input Linear Flow Computer

8

BLANK TABLE INTO WHICH DATA MY BE WRITTEN FOR REF.

K factor and F/V Data Edit Curve

Meter (High Flow) #3


K

Factors

exp

F/V

K

Factors

exp F/V

01

17

02

18

03

19

04

20

05

21

06

22

07

23

08

24

09

25

10

26

11

27

12

28

13

29

14

30

15

31

16

32

6. ANALOGUE INPUT CARD EDIT CURVES

Set Viscosity/ Set S.G.

This section describes how to program Specific Gravity and Viscosity for an individual chemical and its
characteristics.

1) Display shows ‘Temperature’/ ‘Viscosity’ or ‘S.G. ‘set’ or another option

2) Press ALTER to display the first point of calibration. Then use the

ÇÈ keys to select the required calibration

point to be entered or altered. The left hand display will always show the curve and point number i.e. C

101

, the

right hand display will show the units, i.e.

O

C, CTS, S.G. etc. This label can be changed by pressing the SHIFT

then UNIT key.

3) To enter/alter data either press the CLEAR key or enter a numeric value. The display will show SET on the
left indicating that data is being entered. To obtain +/- values press the SHIFT key followed by the +/- key. To
obtain EXP values enter the numeric value followed by the EXP key and the exponential value. Press the
CLEAR key to delete incorrect data entry.

4) Having entered the correct value, press the ENTER key and the entered data with the channel and point
number will be displayed

5) Use the

ÇÈ key to select the next point of calibration or press the ENTER key to exit this mode and return to

the list of program options.

Sort Curve And Vis Temp Etc.


Through out the system each curve can be sorted or left as entered. Each curve works from lowest entry to
highest entry
, if entered this way then the sort routine does not need to be used. If you add a point that is not
the highest then use the sort curve function.