4050 Multi-Input Linear Flow Computer

3

Working Displays (when COX 4050 is powered on)


Refer to programming helper for additional assistance.
When the unit is powered up the serial number is displayed for approximately 5 seconds then the first display

line is shown. The left direction key (

Å)

or the right (

Æ)

can be used to toggle between the

Primary Displays (see table below) and the Secondary Displays (see table below). A message is momentarily
displayed indicating which section is selected. Use the

ÇÈ direction keys to select a display. The same keys

on the hand held remote control would perform the same function.
Press right or left arrow keys to display primary or secondary displays.

Use the up (

Ç)

key or the down (

È)

key to scroll through the resultant displays see table below.

The same keys on the hand held remote control would perform the same function.


Default Primary-

Shows basic values: Visc. Sg, RT (rate), Mas (mass), Tv(total Volume), Tm( total mass),

Temperature.
Tables used to input data.

Primary Display

Description of resultant displays

ident result units

Default Secondary Displays

Manifold (on/off), Volume (on/off), Raw data: (F) requency1, 2,3, Ros, STr, K factor, A1 temp, Date.
Refer to special settings section for changing settings.
Tables used to input data.

Secondary Display

Description of resultant displays

ident result units

To Change idents and units see section titled DISPLAY IDENTS AND UNITS