4050 Multi-Input Linear Flow Computer

10

8. RS232 / RS485
Command Structure.


Viewing data from the Multiflow;

All data is sent and received as ASCII HEX pairs, the maths used in PIC Hex format, 2 example routines are
included to convert this data into PC or ASCII strings. The PIC Hex format is always 4 bytes and represents a
32-bit floating-point number system. To read data use the following format.

Description ID

View

Hub/Slot

Reg/Mem Slot Address No.Bytes CR

String a

V

H R

00A0 04

CR

Hex 61

56

48

52

00A0

04 0D

ASCII Hex

36 31

35 36 34 38

35 32

30 30 41 30 30 34

0D

Notes: Reg/Memory allows the user to view live data within the Processors own working registers or the Flash
memory address space that is used to store constant and curve data. The Hub is the main processor (the card
connected to the serial link), whilst the SLOTs need to be addressed as follows.

Description ID

View

Hub/Slot

Reg/Mem Slot Address No.Bytes CR

String a

V

S M

04

0600 04

CR

Hex 61

56

49

4D 04

0600

04 0D

ASCII Hex

36 31

35 36 34 39

34 44

30
34

30 36 30 30 30 34

0D

SLOT ID

Hex Ascii Hex

Position

4

04 30 34

1A

5

05 30 35

1B

6

06 30 36

1C

7

08 30 38

2A

8

09 30 39

2B

9

0A 30 41

2C

10

0C 30 43

3A

11

0D 30 44

3B

12

0E 30 45

3C

13

10 31 30

4A

14

11 31 31

4B

15

12 31 32

4C

16

14 31 34

5A

17

15 31 35

5B

18

16 31 36

5C

General Address.


To obtain the list address for your instrument please send email to

[email protected]

to request a complete list,

also included are the conversion routines of the PicHex to standard PC/Ascii data.
Char output FAST MEDIUM or SLOW

Computer interface information

Port Settings.


The display shows menu ‘SETUP COMMS’, press ALTER to select the possible sub menus

BAUD

19200

Baud rate change using ALTER to 9600, 1200 or 19200

READ

ONLY

At present the system is set to read only

ID

a

Use ALTER to scan Ids a to z lower case only

RS485

FAST

Delay for bus transceiver FAST MEDIUM or SLOW

COMMS

FAST

Delay between Char output FAST MEDIUM or SLOW