Badger Meter 340LW Series Lonworks Btu Transmitter User Manual

Page 6

Advertising
background image

6

Programming in Comm Mode

Programming the Badger

®

Series 340LW is accomplished by installing the Badger Meter programming

software on a computer and entering data on templates of the Windows

®

based program.

1. Load the interface software into the computer.

2. Connect the computer to the Series 340 transmitter with the Badger Meter Model A-301 communi-

cations cable to the socket labeled COMM PORT, taking care to properly align the tab on the plug
and socket to maintain polarity. Connect the DB9 connector of the Badger Meter Model A301 com-
munications cable to a PC com port that has the Series 340 software installed.

3. Move the Protocol Switch to the Comm Mode.

4. Connect the Series 340 transmitter to a power supply.

5. Open the interface software and select the appropriate COMM PORT as shown in the dialog box

below.

6. Open the Parameters Screen as shown below.

Programming in Comm Mode

Step 7
When programming is complete, be sure to return the “Comm Mode/LonWorks Mode” Switch to the

LonWorks Mode position.

To go to the calibration
settings screen select
“parameters” from either
place shown