Introduction, Specifications – Badger Meter AHL - Hot Tap, High Pressure (2 to 30")" User Manual

Page 3

Advertising
background image

User Manual

Page 3

April 2014

INTRODUCTION

The Preso patented elliptical design outperforms and provides greater

accuracy than traditional differential pressure flow measurement devices .

This differential pressure flow meter is designed with a series of ports

facing the upstream velocity pressures, as well as flow sensing ports

strategically located ahead of the trailing edge flow separation .
The multi-ported, self-averaging flow element consists of an elliptical

shape with two independent flow sensing chambers . The impact velocity

sensing holes (high pressure) are located along the leading edge and the

true static sensing holes (low pressure) are on the exterior probe side .

AHL Annular High Pressure Hot Tap Meter comes with instrument shutoff

valves with provisions to accept a transmitter or direct indicating meter .

Impact Velocity

Sensing Holes

True Static

Sensing Holes

Figure 1: AHL pressure sensing holes

SPECIFICATIONS

Applications

Air, liquids and gases

Pipe Sizes

2…72 in . (50…1829 mm)

Pressure

800 psi (5515 kPa) maximum

Temperature

800° F (426° C) maximum

Accuracy

±0 .75% of reading

Turndown Ratio

17:1 with no vacuum effect

Standard Components

T-type head, 316 SS 1/4 in . or 1/2 in . FNPT connection
CS 3000 lb thread fitting, ASTM A105
316/316L SS Ellipse sensor
Instrument valves (2 per sensor), 1/4 in . or 1/2 in ., CS
316 SS ID tag with wire
150 lb 316/316L SS sensor flange
CS packing chamber with molythane or graphite packing gland
CS packing chamber flange, 150 lb with SS cap
316 SS isolation ball valve, NPT threaded
CS threaded nuts and bolts
CS nipples, schedule 40

Reynolds Number

Greater than 75,000 maintains most accurate flow measurements
Less than 75,000 consult factory for estimated results

Resonance

Less than 0 .8 but greater than 1 .2 . If greater than 0 .8, use double support . System shutdown

is required when the double support option is used . Select larger diameter ellipse to avoid

double support .

Table 1: Specifications

Advertising