Installation instructions, double support – Badger Meter AHL - Hot Tap, High Pressure (2 to 30")" User Manual

Page 5

Advertising
background image

User Manual

Page 5

April 2014

8 . Install the instrument valves (optional) at the pressure connections on the AHL Annular High Pressure Hot Tap Meter

sensor head . Make sure the valves are fully closed before proceeding .

9 . Open the isolating ball valve . Insert the AHL Annular High Pressure Hot Tap Meter sensor into the pipe . Use a wrench to

turn the threaded insertion rods clockwise until the sensor reaches the opposite pipe wall .

10 . Connect the instrument lines to the sensor head valves, then to a gage or transmitter .

SCH/WALL

FLOW METERS
W/O

H

L

FLOW

Field Weld

H

L

SCH/WALL

MOD/β
DIA/ID
CAP
DP
TAG

FLOW METERS
W/O

FLOW

Figure 3: Sensor alignment

INSTALLATION INSTRUCTIONS, DOUBLE SUPPORT

1 . Follow steps 1 through 6 in

“Installation Instructions, Single Support” on page 4

. At 180° from and on the same plane

as the previously drilled hole, grind the surface of the pipe to provide a clean area for welding . Drill a hole and de-burr,

especially on the inside of the pipe . The hole used for the double support should be sized according to

Table 3

.

Model/Sensor

Weld Connector

Drill Bit

AHL (7/8 in .)

1/8 in .

3/8 in .

AHL (1-1/4 in .)

1 in .

7/8 in .

Table 3: Double support drill bit size

2 . Weld the double support thread-o-let, making sure that it is centered with the drilled hole (1/16 in . weld

gap recommended) .

3 . Install the AHL Annular High Pressure Hot Tap Meter sensor through the two holes . Make sure that the double support pin

passes through the guide ring . See