Specifications, Specifications 14 – Badger Meter Oscillating Piston Meter User Manual

Page 14

Advertising
background image

SPECIFICATIONS

1/2"

1"

2"

Minimum Flow Rate, Q Minimum

1 5 gpm

5 5 gpm

25 gpm

Continuous Operating Maximum Rate

4 gpm

20 gpm

65 gpm

Short Duration Maximum Flow, Q Maximum

Continuous operation is acceptable at these rates, but accelerated wear of the

piston and/or bushings may occur

6 gpm

30 gpm

100 gpm

Standard Flange Connections*, Chemical

150* psi ANSI 16 5

150 psi ANSI 16 5

150 psi ANSI 16 5

1/2" Chemical meter can be ordered with 1" flanges for low flow applications on 1" lines All

sizes available with optional 300 psi flanges

Standard Connections, Sanitary

Sanitary OP meters have 3A approval, Ultem piston required

Tri-Clamp

Tri-Clamp

Tri-Clamp

Pressure Drop at

Maximum Continuous Operating Flow

(@ viscosity & specific gravity of water)

1 8 psi

6 3 psi

10 6 psi

Pressure loss increases with fluid viscosity

Maximum Viscosity Limit

10,000 cps (flow range is decreased as viscosity increases)

Contact factory for higher viscosities

Maximum Operating Pressure

150 psi (300 psi optional)

Maximum Operating Temperature

250 °F

Minimum Operating Temperature**

**Minimum temperature for stated accuracy

40 °F

Accuracy

± 0 5% over entire meter flow range

Repeatability

± 0 2% or better under similar repeatable batch operations

Industrial Meter, Oscillating Piston, Sizes 1/2" through 2" Model OP