Performance check, Performance check 8 – Badger Meter Oscillating Piston Meter User Manual

Page 8

Advertising
background image

Installing the Meter

The oscillating piston meters are designed for in-line installation Examples of dimensions of the meter models,

including laying lengths, are shown in

"Figure 3"

After reviewing the applicable dimension requirements, perform the

following procedures:

1 Install appropriate mating connectors in pipeline Provide proper gap length for meter On meters with flanged ends,

allow for gaskets at both inlet and outlet of meter

NOTE:

N

Always install meter in such a way that round cover is on a vertical plane, as shown on

"Figure 2"

2 Install meter in pipeline making sure that flow arrow on housing cover is in proper relation to the direction of flow of

the liquid

3 Depending on meter size and line size, consideration may be given to placing a support under the meter to relieve any

strain on the facility piping caused by meter weight

Performance Check

Check the following to ensure the meter is properly installed and operational

1 Check all piping connections to the meter for proper mating and firm connection
2 Apply fluid pressure to the meter and check connections for possible leaks Retighten connections as required
3 Perform a functional test of the meter using the calibration check and adjustment procedures given in

“Calibration Check and Adjustments” on page 10

Industrial Meter, Oscillating Piston, Sizes 1/2" through 2" Model OP

Page 8

August 2013