Badger Meter 7500 Series Mag Meter User Manual

Installation & operation manual, Badgermeter,inc, Magnetoflow

Advertising
background image

Installation &

Operation Manual

BadgerMeter,Inc.

fi

flow rate of the liquid. The electronic converter measures this

voltage, processes the signal, and provides two digital pulse

outputs, scalable to the desired volumetric value. These digital

pulse outputs can be connected to a batch controller, a total-

izer display unit for monitoring purposes, or to both devices

simultaneously. Magnetoflow

®

7500P operation is not affected

by the presence of suspended solids in the liquid. Variations of

liquid temperature, viscosity or density have no influence in its

principle of operation. A set of convenient, field proven pulse

scaler rotary switches are provided for easy and straight-forward

batch accuracy compensation.

This manual contains information concerning the installation,

operation and maintenance of Badger's Magnetoflow

®

7500P

Mag Flowmeters. To ensure proper performance of the meters

covered, the instructions given in this manual should be thor-

oughly understood. Retain the manual in a readily accessible

location for future reference.

DESCRIPTION AND OPERATION

Badger's 7500P Mag meters are intended for use in fluid

metering applications for process batching in Industrial plants

or concrete operations.

The 7500P Mag meter is a stainless steel flow tube with an

internal isolating lining. Two electromagnetic coils are located

outside the flow tube, diametrically opposed to each other and

protected by a carbon steel housing. Two electrodes, inserted into

the flow tube, are positioned "flush" with the internal diameter of

the tube and perpendicular to the coils. The coils are energized

by a pulsed DC voltage provided by the electronic converter,

and a magnetic field is generated across the flow tube section.

According to Faraday's law, when this magnetic field is "cut"

by the conductive liquid flowing through the meter, a voltage is

generated in the liquid. This voltage is directly proportional to

the liquid flow velocity, and therefore to the actual volumetric

SCOPE OF THIS MANUAL

Coil

DC supply

Electrode

Flow

Liner

Magnetoflow

®

Mag Meter

Model 7500P Meter

IOM-075-04

Part No. 53400-075

3-09

Advertising