Dwyer SPPM-HSG User Manual

Dwyer instruments, inc, Series sppm-hsg weatherproof housing

Advertising
background image

Series SPPM-HSG Weatherproof Housing

Specifications - Installation and Operating Instructions

Bulletin PC-SPPM-HSG

The Series SPPM-HSG Weatherproof Housing was designed to
protect the Series SPPM programmable panel meters from weather and
tampering. Housings can be factory-configured for either 2.4˝ or 2.8˝
panel meters. For added flexibility, the brackets inside of the housing
can be reversed to fit the other display size. The top bracket swivels on
a hinge to allow access to wiring and the mini-USB port on the panel
meter.

Installation

Step 1) Remove the lid by loosening the four screws in the corners of

the lid (screws should stay captured in the lid).

Step 2) Mount the enclosure to the wall or duct.
Step 3) Unscrew the two screws on the bottom of the panel meter

mounting bracket only (as seen in Figure 1).

Step 4) Slide the panel meter through the center hole of the mounting

bracket.

Step 5) For the 2.4˝ model, lift the bottom of the mounting bracket so

that it swivels up exposing the rear of the panel meter (as seen

in Figure 2) and slide the mounting hardware over the rear of
the meter locking it in place.

Step 6) Bring the wire into the enclosure through the conduit hole at the

bottom of the housing and wire the panel meter according to its

instruction manual (Bulletin PC-SPPM).

Step 7) Replace the two screws on the bottom of the panel meter

mounting bracket.

Step 8) Re-attach the lid and tighten the four screws.

SPECIFICATIONS
Service:
Indoor or outdoor.
Material: Painted aluminum and glass.
Enclosure Rating: NEMA 4X (IP66).

DWYER INSTRUMENTS, INC.

Phone: 219/879-8000

www.dwyer-inst.com

P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A.

Fax: 219/872-9057

e-mail: [email protected]

©Copyright 2011 Dwyer Instruments, Inc.

Printed in U.S.A. 6/11

FR# 03-443915-00

MAINTENANCE/REPAIR
Upon final installation of the Series SPPM-HSG, no routine maintenance
is required. The Series SPPM-HSG is not field serviceable and should
be returned if repair is needed. Field repair should not be attempted and
may void warranty.

WARRANTY/RETURN
Refer to “Terms and Conditions of Sales” in our catalog and on our
website. Contact customer service to receive a Return Goods
Authorization number before shipping the product back for repair. Be
sure to include a brief description of the problem plus any additional
application notes.

A

A

REMOVE THESE
SCREWS TO LIFT
TOP PLATE.

SECTION A-A

107° RANGE

OF MOTION

Figure 1

Figure 2

4-23/32

[120]

4-9/64

[105]

4-23/32

[120]

4-9/64

[105]

Ш7/8

[Ш22]

3-37/6

[91]

1-5/32

[30]

*Shown with Series SPPM Panel Meter sold seperately.

Advertising