Dwyer PBLTX User Manual

Mercoid division, Series pbltx submersible level transducer

Advertising
background image

Series PBLTX Submersible Level Transducer

Specifications - Installation and Operating Instructions

Bulletin L-23

The PBLTX Submersible Level Transducer is manufactured

for years of trouble free service in the harshest applications. The

PBLTX measures the height of liquid above its position in the

tank referenced to atmospheric pressure. The transducer con-

sists of a piezoresistive sensing element, encased in a 316 SS

housing. Perfect for wastewater and slurry applications with fea-

tures to protect the unit from these demanding applications.

Large diameter 316 SS diaphragm seal is non-clogging and

damage resistant to floating solids.

Comes equipped with a 270-pound tensile strength, shielded,

vented cable. Ventilation tube in the cable automatically com-

pensates for changes in atmospheric pressure above the tank.

The vent is protected with a maintenance free filter eliminating

particulate or water droplets from entering the transducer.

Intrinsic Safety Approval Classification

The PBLTX is UL listed for use in Hazardous (Classified) Loca-

tions. The protection method is by Intrinsic Safety, “ia”. It was in-

vestigated by UL under UL Standard 913 Sixth Edition and CSA

Standard No. 157-92.

For use in Hazardous (Classified) Locations:

Class I Div. 1 Groups A,B,C,D

Class II Div. 1 Groups E,F,G

Class III Div. 1

Temperature Code: T4 @ 80°C ambient

Install in accordance with control drawing 01-700797-00.

WARNING: To prevent ignition of flammable or

combustible atmospheres, disconnect power be-

fore servicing.

Use with approved safety barriers using entity

evaluation.

SPECIFICATIONS

Service: Compatible liquids.

Wetted Materials: 316 SS, 316L SS, epoxy adhesive; Cable:

Polyether polyurethane or ETFE.

Accuracy: ±0.25% full scale.

Temperature Limit: 0 to 176ºF (-18 to 80ºC).

Compensated Temperature Range: 0 to 176ºF (-18 to 80ºC).

Thermal Effect: Less than ±.02%/ FS/ºF.

Pressure Limit: 2X full scale.

Power Requirement: 10-28 VDC.

Output Signal: 4 to 20 mA DC, two wire.

Response Time: 50 msec.

Max. Loop Resistance: 900 ohms.

Electrical Connection: Wire pigtail.

Mounting Orientation: Suspended in tank below level being

measured. Can be placed on the bottom of the tank on its side.

Weight: 4.3 lb (2.0 kg).

Agency Approvals: CE, UL Intrinsically Safe to UL Standard

913. (See Intrinsic Safety Approval Classification).

The following standards were used for CE approval:

IEC 61000-4-2: 2001

IEC 61000-4-3: 2006

IEC 61000-4-4: 2004

IEC 61000-4-5: 2005

IEC 61000-4-6: 2006

IEC 61000-4-8: 2001

CENELEC EN 55011: 2003

CENELEC EN 61326: 2003

89/336/EEC EMC Directive

MERCOID DIVISION

DWYER INSTRUMENTS, INC.

P.O. BOX 258 • MICHIGAN CITY, IN 46361 U.S.A.

Phone: 219/879-8000

www.dwyer-inst.com

Fax: 219/872-9057

e-mail: [email protected]

Vmax

28VDC

Imax

93mA

Ci

0.051_F

Li

240_H

Entity Parameters

Pi

0.651W

60˚

TYP

ø1/4 x THRU

[ø6.35 x THRU]

ш3-7/16

[ш87.31]

ш1/4 [ш6.35] x THRU

ON A ш1-39/64 [ш40.88] B.C.

8-3/32

[205.58]

2-3/16

[55.56]

BREATHER TUBE

ø1 [25.40]

1/2 NPT

SUBMERSIBLE
CABLE