Overview

This chapter provides information on different methods of connecting your Innnotech

device(s) to your computer, or your LAN for initial configuration. There are several

options available to you and each one is described in detail below. Depending on what

device(s) you are connecting, and how you connect to your LAN will dictate the method

of configuring the Ethernet settings of your device(s) to function on your LAN. Therefore

reference links are provided for you to easily navigate to the appropriate chapter to

configure the Ethernet settings of your device(s).

Genesis II, MAXIM III, MAXIM 1010, and CONV-E

The Genesis II , MAXIM III, and MAXIM 1010 controllers, along with the CONV-E

converter are factory configured for DHCP address assignment, as shown in Table 2-2.

Although it is not recommended to use DHCP IP address assignment for permanent

deployment, these devices can be connected to a LAN with a DHCP server for initial

configuration. Alternatively you can connect these devices to a LAN without a DHCP

server, or connect directly to your computer as described in the sections below.

Connecting to a LAN with DHCP server

When you connect the Genesis II, MAXIM III, MAXIM 1010, or a CONV-E to a LAN

where IP address assignment is handled by a DHCP server, your device(s) should

automatically be assigned an IP address for your particular LAN. You are then ready to

configure the Ethernet settings of your device(s) with the Innotech EtherMate software.

Go to

Chapter 4 – Configuring GenII, MAXIM III, MAXIM 1010, and CONV-E

Connecting directly to a computer

You must use an RJ45 crossover cable when connecting your Innotech device(s) to your

computer. When your Genesis II, MAXIM III, MAXIM 1010, or CONV-E is connected

directly to your computer, or to a LAN with no DHCP server, the IP address will be

assigned by APIPA. Please refer to

Chapter 2 – Dynamic and static IP addressing

for

more information on APIPA. You are then ready to configure the Ethernet settings of

your device(s) with the Innotech EtherMate software.

Go to

Chapter 4 – Configuring GenII, MAXIM III, MAXIM 1010, and CONV-E

IG01, IG03, IG04, and IWS01

The IG01, IG03, and IG04 gateways, along with the IWS01 are factory configured with

a static IP address, as shown in Table 2-2. The Ethernet settings on these devices

are configured using the embedded web server, and therefore it is recommended that

you connect the IG01, IG03, IG04, or IWS01 directly to a computer using an RJ45

crossover cable for initial configuration. You can then configure the Ethernet settings of

your device(s) using the embedded web server. Please note that in order to access the

embedded web server, you must first configure the network settings of your computer to

be on the same network range as the factory default Ethernet settings for these devices.

Go to

Chapter 4 – Configuring IG01, IG03, IG04, and IWS01

Advertising