Rfot product user guide – MadgeTech RFOT Wireless Meat Temperature Data Logger User Manual

Page 15

Advertising
background image

RFOT Product User Guide

Reports can be saved to either the internal file database within the software, or to a file stored on the user’s PC.
By default, new reports are saved to the Reports folder of the internal database in the File Database.

1. Click the tab or window containing the report to be saved.

2. Click the File Button, then click Save.

A dataset is the raw data that is downloaded from a device. This data cannot be altered.
A report is a visual representation of the data that can be changed as desired. Reports are created from datasets.

If the power were to go out or the user’s PC were to crash, the RFOT will still record data to memory. Once the power is
restored the below steps can be taken to obtain the data from the memory of the RFOT.

Downloaded data will remain stored on the device until the device is reset or started.

1. In the device tab in the Control ribbon click on the Download icon.
2. The data from the internal memory of the RFOT will download into the graph.

Data can be interpreted in three different ways, as a Graph, Grid and/or Statistics view.
1. A graph report displays the data graphically.
2. A grid report displays the data in tabular format.
3. The statistics view provides statistics (i.e. minimum, maximum, average, etc.) for the dataset.

To generate a graph, grid, or statistic view from existing data, click on the ‘’Datasets’ folder in the ‘File Database’ panel.
The ‘Datasets’ panel will appear, select a dataset.
1. To generate a graph, in the ‘Report’ ribbon, ‘Graph’ tab control group, click the Generate Graph icon.
2. To generate a grid, in the ‘Report’ ribbon, ‘Grid’ tab control group, click the Generate icon.
3. To generate a statistics report, in the ‘Report’ ribbon, ‘Statistics’ tab control group, click the Generate icon.

1. Click the tab or window containing the report to be saved.
2. Click the file button, then click Save to.
3. Choose the location where the file will be saved.
4. Click Save.

In the Connected Devices list, select the device to be stopped.

On the Device tab, in the Control group, click Stop.

What is the Difference Between a Dataset and a Report?

Wirelessly Downloading from an RFOT

Viewing Data as Reports

Save a Report

To Save to the User’s PC

Stopping an RFOT

11

Advertising