7. Data Sheets

Translated extract from Data Sheet 01

of the EU Prototype Test Certificate PTB 07 ATEX 3047 X

for the three-phase motor, type 1MA7 073-4…

Design values and data

This certificate applies for the following versions on condition that motors of this type only vary to an
insignificant extent from the tested sample with regard to the electrical and thermal load:

Star connection

Torque: 0.5

2.0

2.6

0.8

Nm

Power: 0.005

0.128

0.356

0.224

kW

Voltage: *)

40

200

400

400

V

Current: 0.5

0.92

1.11

0.67

A

Frequency: 5

25

50

100

Hz

Speed of rotation:

102

610

1273

2586

min

-1

Operating mode:

S1

Heat class

F

Delta connection

Torque: 0.5

2.0

2.6

2.6

Nm

Power: 0.005

0.128

0.640

0.764

kW

Voltage: *)

23

115

400

400

V

Current: 0.86

1.59

1.97

1.98

A

Frequency: 5

25

87

100

Hz

Speed of rotation:

102

610

2280

2796

min

-1

Operating mode:

S1

Heat class

F

*) Basic oscillation, measured at the motor terminals.

The voltage depends on the input voltage of the frequency inverter, the voltage drop at the filter and
over the motor supply cable and may not fall below the design value by more than 5% according to
IEC 60034 - 1 Range "A", even with minimum input voltage of the frequency inverter. This must be
taken into account for the design of the motor, the parameterisation of the inverter (e.g. rev/f
adaptation) and for the minimum input voltage of the inverter.

The maximum input voltage of the inverter is 500V.

Adaptation of the design voltage of the motor by means of the number of windings is permissible. The
rated current changes in inverse proportion to the rated voltage.