4. Maintenance
General overhaul
A general overhaul of the motor must be carried out every 5 years.
For this the motor must be dismantled. The following work must be carried out:
• All components of the motor must be cleaned
• All components of the motor must be examined for damage
• All damaged components must be replaced
• All roller bearings must be replaced
• All seals and shaft sealing rings must be replaced
• Measure the insulation resistance
• Check the stationary voltage according to EN 60034-1
The general overhaul must be carried out by qualified personnel in a specialist workshop with
appropriate equipment. We strongly recommend that the general overhaul is carried out by
NORD-Service.