Press, 1200 models, H o l d – Alto-Shaam ecosmart Electronically Operated Ovens User Manual

Page 37

Advertising
background image

OVERNIGHT COOK & HOLD:

D O O R V E N T S :

F I N A L I N T E R N A L T E M P E R AT U R E

O p t i o n a l

O n e - H a l f O p e n

S E E B E L OW

A F T E R OV E R R I D E :

NUMBER

OF SHELVES

ITEMS

PER SHELF

APPROXIMATE

MAXIMUM

CAPACITY

PANS

Lamb, Leg, Boneless, Tied: 8 to 11 lb (4 to 5 kg)

Season as desired and place directly on wire shelves.

E L E C T R O N I C O V E N C O O K I N G G U I D E L I N E S

L A M B , L E G

2 Hours

10 Hours

• Press the HOLD key.

• Press the up and down

arrows to set the

holding temperature…

• Press and release control

ON

/

OFF

key.

• Press and release control

ON

/

OFF

key.

• Press the COOK key.

• Press the up and down arrows to set the cooking

temperature to 250°F (121°C).

• Press the TIME key.

To cook to

MEDIUM

: 10 minutes per pound

for the first roast (22 minutes per kilogram)

plus add 15 minutes for each additional roast.

A D J U S T T I M E F O R O T H E R I N T E R N A L

T E M P E R AT U R E R E Q U I R E M E N T S

.

• Press the COOK key.

• Press the up and down arrows to set the cooking

temperature to 250°F (121°C).

• Press the PROBE key.

• Press the up and down arrows to set the probe

temperature according to the chart shown below.

• Insert the product probe.

P R O D U C T S P E C I F I C AT I O N S a n d P R E PA R AT I O N

M I N I M U M H O L D I N G T I M E R E Q U I R E D

M A X I M U M H O L D I N G T I M E

O V E R R I D E A L L O WA N C E :

2 5 ° F ( 1 4 ° C )

CLOSE THE OVEN DOOR

.

WAIT FOR THE AUDIBLE SIGNAL

TO INDICATE OVEN HAS PREHEATED

.

CLOSE THE OVEN DOOR

.

WAIT FOR THE AUDIBLE SIGNAL

TO INDICATE OVEN HAS PREHEATED

.

1

2

2

3

3

1 Roast

2 Roasts

6 Roasts

4 Roasts

4 Roasts

1 Roast

4 Roasts

12 Roasts

12 Roasts

12 Roasts

up to 40 lb (18 kg)

up to 100 lb (45 kg)

up to 100 lb (45 kg)

up to 100 lb (45 kg)

none

none

none

none

none

AS-250

500

SERIES

750

SERIES

1000

SERIES

1200

MODELS

• Press the HOLD key.

• Press the up and down

arrows to set the

holding temperature…

PRESS

PRESS

T H E T I M E A N D P R O B E T E M P E R AT U R E A R E S U G G E S T E D G U I D E L I N E S O N LY

.

A L L C O O K I N G S H O U L D B E B A S E D O N I N T E R N A L P R O D U C T T E M P E R AT U R E S

.

D U E T O VA R I AT I O N S I N P R O D U C T Q U A L I T Y

,

W E I G H T

,

A N D D E S I R E D D E G R E E O F D O N E N E S S

,

T H E C O O K I N G T I M E R O R P R O B E T E M P E R AT U R E M AY N E E D T O B E

A D J U S T E D A C C O R D I N G LY

.

A LWAY S F O L L O W L O C A L H E A LT H

(

H Y G I E N E

)

R E G U L AT I O N S F O R A L L I N T E R N A L T E M P E R AT U R E R E Q U I R E M E N T S

.

35.

TO C O O K B Y P RO B E

TO C O O K B Y T I M E

T I M E R E Q U I R E D I N

" H O L D "

C Y C L E B E F O R E S E RV I N G

.

SERIES

PER COMPARTMENT

HOLDING TEMPERATURES

RARE

: 140°F (60°C)

MEDIUM RARE

: 145°F (63°C)

MEDIUM

: 150°F (66°C)

MEDIUM WELL

: 160°F (71°C)

WELL

: 160°F (71°C)

PROBE TEMPERATURE SETTINGS

RARE

: 105°F (41°C)

MEDIUM RARE

: 110°F (43°C)

MEDIUM

: 115°F (46°C)

MEDIUM WELL

: 125°F (52°C)

WELL

: 135°F (57°C)

HOLDING TEMPERATURES

RARE

: 140°F (60°C)

MEDIUM RARE

: 145°F (63°C)

MEDIUM

: 150°F (66°C)

MEDIUM WELL

: 160°F (71°C)

WELL

: 160°F (71°C)

FINAL INTERNAL TEMPERATURE

RARE

: 130°F (54°C)

MEDIUM RARE

: 135°F (57°C)

MEDIUM

: 145°F (63°C)

MEDIUM WELL

: 150°F (66°C)

WELL

: 160°F (71°C)

Advertising