The allocation of special error codes for Nord inverters is carried out as follows:
Error code
Error register
FI error number
(corresponds to (P700))
Explanation
0x0000 0
0x1000 1
---
The error number transmitted by FI is not known to the
technology unit. It must be read out via (P700) or an
actual value.
0x2200
3
4.0 / 4.1
0x2310 3
3.0
0x2311 3
3.2
0x2312 3
3.3
0x3110 5
5.1
0x3120 5
6.1
0x3130 5
7.0
0x3210 5
5.0
0x3230 5
6.0
0x4210 9
1.1
0x4310
9
2.0 / 2.1 / 2.2
0x5000 1
10.8
0x5110 1
11.0
0x5300 1
17.0
0x5510 1
20.0
0x5520 1
20.8
0x5530 1
8.2
0x6000
1
20.1 to 20.7 / 21.3
0x7112 3
3.1
0x7120
1
16.0 / 16.1
0x7305 1
13.0
0x8100
17
10.0 / 10.1 / 10.2
0x8111
17
10.3 to 10.7 / 10.9
0x8300 1
13.2
0x8400 1
13.1
0x9000 1
12.0
0xFF00 129
18.0
0xFF10 129
19.0
Meaning:
see frequency inverter manual.