Parameter
Setting value / Description / Note
Supervisor
Parameter
set
Available with option
P422
Digital input function 3
BSC
STD
0 ... 48
[ 2 ]
Enable left
as factory setting, control terminal 23
Various functions can be programmed. These can be seen in the following table.
P423
Digital input function 4
BSC
STD
0 ... 48
[ 8 ]
Parameter set switching Bit 0
as factory setting, control terminal 24
Various functions can be programmed. These can be seen in the following table.
P424
Digital input function 5
STD
0 ... 48
[ 4 ]
Fixed frequency 1
(P429) as factory setting, control terminal 25
Various functions can be programmed. These can be taken from the following table.